P0BC0
- Powertrain
- Generic (SAE)
Get it looked at now
Driving may cause further damage or leave you stranded. Arrange service promptly rather than waiting.
Hybrid/EV Battery Pack Cooling Fan Supply Voltage Circuit Low
This code is in our catalogue but has not yet been through editorial review, so the guidance below is limited to what our structured data supports. We publish deeper diagnostic content only after a code has been reviewed — here is why.
The supply voltage circuit of the HV battery pack cooling fan reports a circuit low condition. Cooling fan operation may be impaired.
A trouble code records what a control module measured. It does not identify which part failed. Test before replacing anything.
- Safe to drive
- Driving may cause further damage or leave you stranded. Arrange service promptly rather than waiting.
- Urgency
- Get it looked at now
- Will it pass emissions
- Not affected
- Check engine light
- Solid
- EV/hybrid system warning light on
- Reduced power output or limp mode
- Charging may fail or be slowed
- Reduced electric range
Many vehicles show no symptom at all beyond the warning light. The absence of a symptom does not mean the fault is not real.
| # | Cause | How often | Component |
|---|---|---|---|
| 1 | Wire shorted to ground | Very common | — |
| 2 | Supply rail collapsed | Common | — |
| 3 | Connector pins corroded - high contact resistance | Occasional | — |
Ordering reflects how often each cause is responsible in general, not a probability for your vehicle. Confirm by testing.
- HV Battery Cooling Fan Supply
- Wiring Harness
- BMS
- Definition
- Generic code set (SAE J2012 / ISO 15031-6) via the OBDexopen database, dedicated to the public domain under CC0-1.0.
- Diagnostic guidance
- Written and reviewed in-house. See our editorial policy.
- Review status
- Awaiting review
Found something wrong? Tell us — we publish corrections.