P202F
- Powertrain
- Manufacturer-specific
- Emissions
Diagnose soon
Usually safe to drive short distances, but the fault will not clear itself and can worsen or fail an emissions test.
Reductant/Regeneration Supply Control Circuit Range/Performance
This code is in our catalogue but has not yet been through editorial review, so the guidance below is limited to what our structured data supports. We publish deeper diagnostic content only after a code has been reviewed — here is why.
The control line that gates the DEF supply pump or the regeneration heating circuit does not respond as commanded — duty cycle, current draw, or response time off-spec.
A trouble code records what a control module measured. It does not identify which part failed. Test before replacing anything.
- Safe to drive
- Usually safe to drive short distances, but the fault will not clear itself and can worsen or fail an emissions test.
- Urgency
- Diagnose soon
- Will it pass emissions
- No
- Check engine light
- Solid
- Check engine light or NOx warning on
- AdBlue/DEF level or quality warning
- Possible no-start countdown after ignore period
- Failed emissions inspection (NOx)
Many vehicles show no symptom at all beyond the warning light. The absence of a symptom does not mean the fault is not real.
| # | Cause | How often | Component |
|---|---|---|---|
| 1 | Supply relay aged or pitted contacts | Very common | — |
| 2 | Supply pump motor brushes worn | Common | — |
| 3 | Sensor element aged beyond calibration window | Occasional | — |
Ordering reflects how often each cause is responsible in general, not a probability for your vehicle. Confirm by testing.
- Reductant Supply Pump
- Reductant Supply Relay
- Definition
- Generic code set (SAE J2012 / ISO 15031-6) via the OBDexopen database, dedicated to the public domain under CC0-1.0.
- Diagnostic guidance
- Written and reviewed in-house. See our editorial policy.
- Review status
- Awaiting review
Found something wrong? Tell us — we publish corrections.